navigation bypass navigation contact us ring status schedules user guide links notices user sites people and policies jobs safety publications meetings microscopes specifications About the ALS science highlights ALSNews home
 

 


 

Beamline 7.2

Diagnostic Beamline

Operational

Now

Source characteristics

Bend magnet

Energy range

Port 1: ~17 keV transmission though Mo filters

Port 2: IR–visible from large-angle synchrotron radiation; UV–x-ray for beam position monitor (BPM)

Endstations

Port 1: Hard x-ray to visible converter (phosphor)

Port 2: None (available for temporary experiments)
Both ports are inside the ALS shielding.

Characteristics

Port 1: Pinhole-based x-ray system for transverse measurements

Port 2: IR/visible port available for temporary experiments; x-ray BPM based on electron secondary emission induced in metallic blades by synchrotron radiation

Spatial resolution

Port 1: <25 µm transverse

Port 2: ~1 µm position; <1 µrad angle (x-ray BPM)

Detectors

Port 1: Analog CCD camera

Port 2: Secondary emission copper blades (x-ray BPM)

Scientific applications

Storage ring diagnostics, accelerator physics

Local contact/spokesperson

Name: Fernando Sannibale
Affiliation: Advanced Light Source, Berkeley Lab
Phone: (510) 486-5924
Fax: (510) 486-4960
Email: fsannibale@lbl.gov

 