Diffraction Microscopy
Scientific disciplines: Applied science, biology, polymers, soft materials.
Endstations:
| GENERAL BEAMLINE INFORMATION |
|
Operational
|
Yes.
|
| Proposal cycle |
Proposals for Structural Biology Beamlines (2-month cycle) |
|
Source characteristics
|
10-cm period undulator (U10)
|
|
Energy range
|
500-1500 eV
|
|
Monochromator
|
Either none or an off-axis zone-plate monochromator that will provide a focused beam with bandwidth of about 0.1%
|
|
Calculated flux (1.9 GeV, 400 mA)
|
2.8 x 1015 photons/s/1%BW/central cone at 457 eV
|
|
Resolving power (E/ΔE)
|
Undulator bandwidth or 1,000
|
|
Endstations
|
Serial crystallography
Diffractive imaging
Nanosurveyor
|
| Scientific disciplines |
Applied science, biology, polymers, soft materials. |
|
Spokesperson
|
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
University of Oregon Phone: (541) 346-4742 Fax: (541) 346-3422 |
|
Local contact
|
David Shapiro Advanced Light Source, Berkeley Lab Phone: (510) 486-7628 Fax: (510) 486-7696
|
| ENDSTATION INFORMATION |
|
Endstation name
|
Serial crystallography
|
|
Detectors
|
CCD
|
| Spatial resolution |
2 nm |
| Spot size at sample |
50 µm |
|
Sample format
|
Protein nanocrystals
|
|
Sample environment
|
Droplet jet
|
|
Special notes
|
Endstation separated from beamline by cooled window
|
| ENDSTATION INFORMATION |
|
Endstation name
|
Diffractive imaging
|
|
Detectors
|
CCD
|
| Spot size at sample |
10 µm |
|
Sample format
|
Micron size particle
|
|
Sample preparation
|
Can be cryo
|
|
Sample environment
|
Droplet jet
|
|
Special notes
|
Endstation separated from beamline by cooled window
|
| ENDSTATION INFORMATION |
|
Endstation name
|
Nanosurveyor
|
|
Detectors
|
Fast CCD
|
| Characteristics |
Ptychography |
| Spatial resolution |
10 nm |
| Spot size at sample |
300 nm |
|
Sample format
|
Micron thick particles
|
|
Sample environment
|
High vacuum
|
|
Special notes
|
Endstation separated from beamline by cooled window
|
|