Beamline 4.0.2 Print

 

Magnetic Spectroscopy and Scattering

 

Scientific disciplines: Magnetism, materials science

 

Endstations:

 

GENERAL BEAMLINE INFORMATION
Operational Yes

Source characteristics

5.0-cm period elliptical polarization undulator (EPU5)

Energy range

100-2000 eV

Monochromator

Variable-included-angle PGM

Calculated flux (1.9 GeV, 400 mA)

1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.]

Resolving power (E/ΔE)

5,000-10,000 (at source-size limit; energy-dependent)
>25,000 (64 eV, 10-mm entrance/exit slits)

Special notes

Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

Local contact

This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Advanced Light Source, Berkeley Lab
Phone: (510) 486-4834
Fax: (510) 486-7588

 

 

Beamline phone number

(510) 495-2041

Website

http://ssg.als.lbl.gov/ssgdirectory/arenholz/BL402.html

 

ENDSTATION INFORMATION

Endstation name

Eight-pole electromagnet

Characteristics

Magnetic fields up to 0.9 T can be applied in any direction relative to the incoming x-ray beam

Detectors

Total electron yield, total fluorescence yield, transmission

Spot size at sample

100 micron x 100 micron or larger

Samples

Solid samples

Sample environment

10-6 to 10-9 Torr, 15 to 450 K

Scientific applications

Spectroscopy on ferro- and antiferromagnetic materials

Experimental techniques

XAS, XMCD, XMLD measurements

 

ENDSTATION INFORMATION

Endstation name

Scattering chamber

Detectors

Princeton CCD, photodiodes

Spot size at sample

100 micron x 100 micron or larger

Samples

Solids (single crystals, thin films)

Sample environment

UHV

Scientific applications

Probing charge, orbital and spin order; interfaces in thin film superlattices

Experimental techniques

Resonant soft x ray scattering; x-ray reflectivity; x-ray magnetic dichroism

 

ENDSTATION INFORMATION

Endstation name

9T Magnet

Detectors

9-Tesla superconducting magnet, 10 K sample temperature

Spot size at sample

180 micron x 180 micron or larger

Samples

Solids (single crystals, thin films)

Sample environment

UHV

Scientific applications

Spectroscopy on magnetic materials and correlated systems

Experimental techniques

X-ray absorption (Electron yield, transmission), x-ray magnetic dichroism