Surface and materials science, soft x-ray fluorescence (SXF), open port
Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system
Endstations:
| GENERAL BEAMLINE INFORMATION |
|
Operational
|
Yes
|
| Proposal cycle |
Proposals for General Sciences Beamlines (6-month cycle) |
|
Source characteristics
|
5-cm period undulator (U5) (first, third, and fifth harmonics)
|
|
Energy range
|
80-1250 eV
|
|
Monochromator
|
SGM (gratings: 150, 380, 925 lines/mm)
|
|
Flux (1.9 GeV, 400 mA)
|
1011 to 6 x 1015 photons/s (resolution and energy dependent)
|
|
Resolving power (E/ΔE)
|
7000
|
| Scientific disciplines |
Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system. |
|
Endstations
|
8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS
|
|
Local contact
|
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Advanced Light Soucrce, Berkeley Lab Phone: (510) 486-4989 Fax: (510) 495-2067 |
|
Spokesperson
|
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
University of Wisconsin, Madison (608) 263-5590 (608) 265-2334
|
|
Beamline phone numbers
|
(510) 495-2080, (510) 495-2089
|
| Website |
http://bl8.lbl.gov/ |
| ENDSTATION INFORMATION |
|
Endstation name
|
8.0.1.1 Soft x-ray fluorescence (SXF) spectrometer
|
| Operational |
Yes |
| Detector |
Roland Circle x-ray spectrometer |
|
Characteristics
|
Measures the soft x-ray emission from solid samples with a dispersive grating spectrometer
|
|
Spot size at sample
|
100 (h) x 1000 (v) µm
|
|
Sample format
|
UHV-compatible solids up to 2 cm in diameter; 5-mm diameter optimal
|
|
Sample environment
|
UHV
|
|
Special notes
|
Sample transfer capabilities
|
|
Experimental techniques
|
XAS, XES, RIXS
|
| ENDSTATION INFORMATION |
|
Endstation name
|
8.0.1.2 Open Port
|
| Operational |
Yes |
|
Characteristics
|
Hosts 8 different roll-up endstations
|
| Detector |
Endstation dependent |
|
Spot size at sample
|
100 (h) x 35 (v) µm
|
|
Sample format
|
Solids, liquid, gas (endstation dependent)
|
|
Sample environment
|
Endstation dependent
|
|
Scientific applications
|
Strong correlated system, magnetic, AMO, liquid, etc.
|
| ENDSTATION INFORMATION |
|
Endstation
|
8.0.1.3 Wet-RIXS
|
|
Operational
|
Yes, but not open to users
|
| Detector |
Channeltron |
|
Spot size at sample
|
100 (h) x 35 (v) µm
|
|
Sample format
|
Solid, liquid, gas.
|
|
Sample environment
|
UHV with in-situ cells
|
|
Scientific applications
|
In-situ x-ray spectroscopy
|
| ENDSTATION INFORMATION |
|
Endstation
|
8.0.1.4 Nano-NEXAFS
|
|
Operational
|
Yes
|
| Detector |
MCP |
|
Spot size at sample
|
100(h) x 30(v) µm
|
|
Sample format
|
Solids
|
|
Sample environment
|
UHV
|
|
Scientific applications
|
XAS, nanosciences, surface sciences
|
| ENDSTATION INFORMATION |
|
Endstation
|
8.0.1.5 Bio-NEXAFS
|
|
Operational
|
Yes, but not open to users
|
| Detector |
MCP |
|
Spot size at sample
|
Up to 1 cm x 1 cm
|
|
Sample format
|
Organic, solids.
|
|
Sample environment
|
UHV
|
|
Scientific applications
|
Biological, bio-mimetic, organic material sciences.
|
|