LBNL Masthead A-Z IndexBerkeley Lab mastheadU.S. Department of Energy logoPhone BookJobsSearch
Beamline 8.0.1 Print

 

Surface and materials science, soft x-ray fluorescence (SXF), open port

 

Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system

 

Endstations:

 

GENERAL BEAMLINE INFORMATION

Operational

Yes

Proposal cycle Proposals for General Sciences Beamlines (6-month cycle)

Source characteristics

5-cm period undulator (U5) (first, third, and fifth harmonics)

Energy range

80-1250 eV

Monochromator

SGM (gratings: 150, 380, 925 lines/mm)

Flux (1.9 GeV, 400 mA)

1011 to 6 x 1015 photons/s (resolution and energy dependent)

Resolving power (E/ΔE)

7000

Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

Endstations

8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer
8.0.1.2: Open port
8.0.1.3: Wet-RIXS
8.0.1.4: Nano-NEXAFS
8.0.1.5: Bio-NEXAFS

Local contact

This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Advanced Light Soucrce, Berkeley Lab
Phone: (510) 486-4989
Fax: (510) 495-2067

Spokesperson

This e-mail address is being protected from spambots. You need JavaScript enabled to view it
University of Wisconsin, Madison
(608) 263-5590
(608) 265-2334

Beamline phone numbers

(510) 495-2080, (510) 495-2089

Website http://bl8.lbl.gov/

 

ENDSTATION INFORMATION

Endstation name

8.0.1.1 Soft x-ray fluorescence (SXF) spectrometer

Operational Yes
Detector Roland Circle x-ray spectrometer

Characteristics

Measures the soft x-ray emission from solid samples with a dispersive grating spectrometer

Spot size at sample

100 (h) x 1000 (v) µm

Sample format

UHV-compatible solids up to 2 cm in diameter; 5-mm diameter optimal

Sample environment

UHV

Special notes

Sample transfer capabilities

Experimental techniques

XAS, XES, RIXS

 

ENDSTATION INFORMATION

Endstation name

8.0.1.2 Open Port

Operational Yes

Characteristics

Hosts 8 different roll-up endstations

Detector Endstation dependent

Spot size at sample

100 (h) x 35 (v) µm

Sample format

Solids, liquid, gas (endstation dependent)

Sample environment

Endstation dependent

Scientific applications

Strong correlated system, magnetic, AMO, liquid, etc.

 

ENDSTATION INFORMATION

Endstation

8.0.1.3 Wet-RIXS

Operational

Yes, but not open to users

Detector Channeltron

Spot size at sample

100 (h) x 35 (v) µm

Sample format

Solid, liquid, gas.

Sample environment

UHV with in-situ cells

Scientific applications

In-situ x-ray spectroscopy

 

ENDSTATION INFORMATION

Endstation

8.0.1.4 Nano-NEXAFS

Operational

Yes

Detector MCP

Spot size at sample

100(h) x 30(v) µm

Sample format

Solids

Sample environment

UHV

Scientific applications

XAS, nanosciences, surface sciences

 

ENDSTATION INFORMATION

Endstation

8.0.1.5 Bio-NEXAFS

Operational

Yes, but not open to users

Detector MCP

Spot size at sample

Up to 1 cm x 1 cm

Sample format

Organic, solids.

Sample environment

UHV

Scientific applications

Biological, bio-mimetic, organic material sciences.